|

|
Thermo Tracer H2640


ÃÖ°í ¼º´ÉÀÇ 640×480 ȼÒ
°í ºÐÇØ´É ¼¾¼ žÀç!
|

|
Measuring range : -40 to 500°C
Resolution : 0.06°C or better at 30°C (30Hz)
High resolution : 640 x 480-pixel detector
Accuracy : ±2%(of reading) or ±2°C
Measurement distance : 30cm to ¡Ä
Frame time : 30 frames/sec
Visible camera : 1.3M pixels, color
Display : Wide 5.6-inch LCD & color viewfinder
Interface : IEEE1394/USB2.0/CF Card
|
 |
|

|
Advanced Thermo TVS-500EX

µ¿±Þ ÃÖ°í ¼º´ÉÀÇ
¼¸ð±×¶óÇÇ
|

|
Measuring range : -40 to 500¡É:Standard to 2000(with optional high temperature filter)
Temperature resolution : Better than 0.05¡É with Averaging
Accuracy : ±2¡É or ±2% *1
Measurement distance : 30cm to ¡Ä
Frame time : 1/60 seconds
Effective pixels : 320(H)×240(V)
Visible camera : 640×480
Display : 3.5" color LCD monitor Inverted display
Interface : RS-232C,USB, IEEE1394(option) *2
|
 |
|

|
Advanced Thermo
TVS-500EXZ

±¤ÇÐ ÁÜ Ã¤¿ëÀÇ ÃÖ°í ¸ðµ¨
|

|
Measuring range : -40 to 500¡É:Standard to 2000(with optional high temperature filter)
Temperature resolution : 0.1¡É or less
Digital zoom : x2, x4(scroll display, area designation possible)
Measurement distance : 30cm(f=10mm) ~ ¡Ä
Frame time : 1/60 seconds
Effective pixels : 320(H)×240(V)
Visible camera : 640×480
Display : 3.5" color LCD monitor Inverted display
Interface : CF Card
|
 |
|

|
Thermo Tracer
TH9100MR/WR

°í¼ÓÀ¸·Î º¯ÈÇÏ´Â ÃøÁ¤
´ë»ó¹°ÀÇ °èÃøÀÌ ¿ëÀÌ
|

|
Measuring range : -20 to 100°C*1 / 0 to 250°C*2
Resolution : 0.02°C (TH9100MR at 30°C, ¥Ò64)
Accuracy : ±2°C or ±2% of reading, whichever is greater
Measurement distance : 30cm to ¡Ä
Effective pixels : 320 (H) x 240 (V) pixels
Visible camera : 752 (H) x 480 (V) pixels
Movie recording : Real-time memory : 1664 images (max. 60Hz)
Display : View finder and 3.5-inch color LCD
Interface : IEEE1394, RS-232C, CF card
|
 |
 |
Handy Thermo
TVS-200EX

Àú °¡°Ý °í ¼º´ÉÀÇ
¼¸ð±×¶óÇÇ
|

|
Measuring range : -20 to 500¡É:Standard to 2000¡É
(with optional high temperature filter)
Resolution : Better than 0.08¡É with Averaging
Accuracy : ±2¡É or ±2% *1
Measurement distance : 30cm to ¡Ä
Frame time : 1/60 seconds
Effective pixels : 320(H) × 240(V)
Visible camera : 640x480
Display : 3.5" semi-transmissive color LCD
monitor
Interface : RS-232C, IEEE1394(option)*2, CF Card
|
 |
|

|
Thermo Tracer
TH7800N

¿È»ó°ú °¡½Ã È»óÀÇ
ÇÕ¼º Ç¥½Ã ±â´É žÀç
|

|
Measuring range : -20 to 100°C*1 / 0 to 250°C*2
Temperature resolution : 0.1°C(at 30°C,*1)
Accuracy : ±2°C or ±2% of reading whichever greater
Measurement distance : 30cm(f=10mm) ~ ¡Ä
Frame time : 1/60 seconds
Effective pixels : 320(H)×240(V)
Visible camera : 752(H) x 480(V) pixels
Display : 3.5 inch LCD monitor with auto switch
Interface : USB2.0 (Mass storage mode)
|
 |
|

|
Thermo Shot F30W


È޴뼺, Á¶ÀÛ¼ºÀÌ ¶Ù¾î³
ÈÞ´ë¿ë ¼¸Ó±×¶óÇÇ
|

|
Measuring range : -20 to 350¡É
Temperature resolution : 0.2¡É(0.1¡É with S/N improvement)
Accuracy : ±2¡É or ±2% whichever is greater
Measurement distance : 10cm to infinity£¨Temp accuracy not assured at 50cm or closer.£©
Frame time : 8.5 frames/sec
Display : 2.7" LCD
Interface : USB2.0
|
 |
 |
Monitoring Control Thermo TVS-50SC

°¨½ÃÁ¦¾î¿ë ¼¸ð±×¶óÇÇ
|

|
Measuring range : -40~500¡É:Standard
~2000¡É (with optional high temperature filter)
Resolution : 0.08¡É or less(when S/N improvement is applied)
Accuracy : ±2°C for object less than 100¡É
±2°C for object more than 100±2°C or highter(temperature range -20~300°C)
Measurement distance : 30cm to ¡Ä
Interface : RS-232C,IEEE1394 or Ethernet(preset by mode)
|
 |
 |
Thermo Tracer
TS9230

FA/ »ý»ê ¶óÀÎ/º¸¾ÈÀ» À§ÇÑ °í¼º´É °¨½Ã¿ë
|

|
Measuring range : -40¡É to 500¡É (Range 1: -40 to 120¡É, Range 2: 0 to 500¡É) (Select either
standard or option) Option: 200 to 2000¡É
Accuracy : ±2%(Reading) or ±2¡É
Measurement distance : 30cm to ¡Ä
Frame time : 60 frames/sec
Interface : RS232C IEEE1394a (6pin) : Option Ethernet (100/10baseT) :
Option **Users can select only one of IEEE1394 or Ethernet.
|